Instructions

This calculator allows you to calculate the "Moisture Vapor Emissions Rate" as prescribed by ASTM F-1869 and ASTM E-1907.

The program is designed for maximum flexibility while providing guidance and verifying compliance with code requirements.  Click on any of the for help on the adjacent field.

Any time a choice is made or a value changed the calculator will display the updated result.
When a value entered is not a number, or is wrong (hour larger than 24; initial weight smaller than 27 grams...) the calculator alerts the user and moves to the field that needs to be corrected.

You can choose to exclude the dish area as required by ASTM (default), or include it as suggested by others.  When you click on the "exclude" button, the calculator uses the constant 118.932 instead of 108.846.

The start date is NOT used in the calculations and can be omitted.  It is provided here for inclusions in the printed report

Use this field to enter an identifier for each record.  It will be copied to the summary table later.

Enter the day of week when the test started and the day of week when it ended by selecting from the lists.  These are used in calculating the actual time for the test.

Enter the start and end time information needed to calculate the total hours.   Enter the time as hh:mm using the 24 hour format (4 PM is entered as 16).  Leading zeroes are not needed (9 or 09).  You  will get feed-back regarding compliance with ASTM requirements of 60-72 hours.

Enter the weight at start and end in grams.  The calculator will display the weight gain and the Vapor Emissions.

The total time between start and end is displayed here in hours.

The total weight gain (in grams) as calculated from the initial and final weight.

The message area is used to provide feed-back and instructions.

The calculated Vapor Emissions is displayed here.  This value is calculated every time a value is changed in any of the input fields.

Use the notes area to add information you wish to record with the test results.  These may be an address, location, temperature and humidity...  This area is currently limited to 125 characters.

Click the submit button to calculate Emissions after changing a value in any field.  Pressing the "tab" key or clicking the mouse anywhere on the form (outside the changed field) will have the same result.

The "Copy to table" button copies the information currently displayed in the calculator into a table below.  Make sure to click it after each calculation.  When done, you may print the page or copy the whole table to another screen for printing (use link on the right).

The "Erase table and restart" link will erase the summary table without losing the data currently entered in the form.  Previous result summaries will be erased  (use link on the right).

To calculate another test done at the same dates click the "Another Test" button.  This button will clear all the fields that are expected to change (Minutes and weights) while leaving the rest of the information as entered last.

Click the "Clear Form" button to remove all entered data and restore the calculator to its default display.

Click the example button to see an example of properly filled form and its calculations.  This may help where this explanation is not clear enough...

For easier and cleaner printing it is now possible to copy the summary table to a new browser window.  from there you may easily export the table into a spreadsheet or word-processor for further formatting and saving.

Enjoy.